Pvc Pipe Electrical Conduit Sizes Chart

We are providing this page as a courtesy to electricians as a fast reference for schedule 40 pvc conduit.
Pvc pipe electrical conduit sizes chart. Order the pipe viper you may bend schedule 40 pvc or conduit into any configuration. Pvc pipe sizes are different than the size the pipe is called. Below are a series of pvc pipe diagrams and dimension charts to help. The wall thickness continues increasing as the pipe gets.
Fittings follow this same pattern a 1 fitting has a 1 315 inch opening to accept a 1 inch pipe which actually measures 1 315 inches in diameter. Pvc conduit for electrical wiring poly vinyl chloride. Selecting the right pvc conduit for electrical wiring. Pvc pipe sizes dimensions guide charts when it comes to the pvc pipes themselves there are 3 key metrics.
If the nominal size is the id then that means 1 2 pvc pipe walls are 170 thick and 3 pvc pipe walls are 0 250 thick. Formufit internal fit products such as internal dome caps adjustable elbows internal couplings and other products that fit inside of the pvc pipe will not work with sch 80 pvc due to the smaller internal diameter. Schedule 80 pvc pipe is only compatible with formufit external fit products. Carlon schedule 40 and schedule 80 conduits are designed for use.
60 c 75 c 90 c 60 c 75 c 90 c 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 3 1 2. If you re using electrical metal tubing emt conduit you ll see that the closest size that you need is a 1 in conduit which gives you a 39 fill. The results show the allowable number of wires for each size type of conduit and wire based on the 2020 nec code. Each column going up and down is a different gauge of wire.
Find the type of conduit that you want to use in table 4. The od for 1 2 pvc pipe is 0 840 and the od for 3 pvc pipe is 3 500. Size copper aluminum diameter wires in conduit. Outer diameter inside diameter and wall diameter as in wall thickness.
For example a 1 inch pvc pipe is actually 1 315 inches in outside diameter and 1 029 inches in inside diameter. The inside diameter of schedule 40 pvc conduit is larger because the wall of the conduit is thinner. Each row going across is a different size of pvc conduit schedule 40 or 80. The outside diameter of both sch 40 and sch 80 is the same.
Click to open the pdv version of our pvc pipe and fittings sizes guide. To find pvc pipe od sizes you cannot simply add a certain amount to the size on the label. Just select the conduit type and the wire insulation to get a quick table of conductor properties. Pvc schedule 80 sizes table.